Concourse CI/CD devops prometheus kubernetes monitoring modbus kepware c-programming IoT golang telegram bot python cli urwid elasticsearch aws ecs apache spark scala AWS EMR hadoop webhooks ssl nginx digital-ocean emr apache pig datapipeline found.io elastic-cloud rails try capybara docker capistrano heka bigquery kafka protobuf vim iterm javascript emberjs git scripting dnsmasq bem frontend meteorjs meteorite heroku

Programming with the Modbus RTU & TCP/IP Protocol

Today’s post probably has a very different audience- modbus protocol; it’s nowhere near the web projects that I’ve been doing so far but definitely something I’m super interested in. This project mostly works with the modbus protocol, which is an open, communication protocol used for transmitting information over serial lines between hardware devices. Given that IoT is becoming more and more relevant and that the modbus protocol, while old, is still a very commonly used protocol in the IoT world. So, I hope people will find this post interesting, or even useful if you’re attempting something similar.

Backstory

The backstory of the project is that I needed a program to read some data from a spindle, as well as control it through an inverter- the hitachi wj200 over the Modbus RTU protocol. At the same time, it also needs to relay some of this information to a KepwareServer that acts as both a Modbus TCP/IP slave and a OPC/UA server. This then, in turn allows communication with other OPC/UA clients.

The project was initially developed and tested on OSX Sierra 10.12.6 but was eventually compiled and ran on a Windows 10 so that the program can just talk to Kepware over modbus TCP instead of needing 2 machines: 1 linux/OSX + external cabling to a windows machine (Kepware only runs on windows), but it was also tested on OSX Sierra 10.12.6 first.

You can find the reference code here: https://github.com/aranair/modbus_adapter.

Simplified Demo

If you’re just here to find some sample code that runs a Modbus client and server, you can check out the simplified branch from the repo above. The master and slave code should work with each other.

Setup

The hardware setup looks roughly like this:

Spindle <> hitachi wj200 <> USB/COM converter <> C program <> Kepware <> OPC/UA

In this post though, I’ll focus on the first part (from the left) of the setup, up to the C program. The C program was written and tested on my Mac at first so I’ll talk a little bit on that. In the next post, I’ll shift the focus to Kepware and how I compiled the same program in Windows 10 (which turned out to be harder than I thought it should be because of some dependencies I used).

Modbus Masters vs Slaves

I am not going to go into details of the Modbus protocol, you can head over here if you want a quick overview of the actual protocol like how to write_registers and write_coil e.g. but I’ll like to talk about something I was initially confused about.

It was the concept of masters, slaves, clients and servers in Modbus. The two different ways of definition that are sometimes used interchangeably in documentations makes it harder to remember which is which, at least for me. So, before moving ahead with the rest of the stuff, I should probably define it here again so that it’s less confusing for the unfortunate souls who might read on lol.

Master / Client

The master in a modbus network is the brain that is in charge of controlling devices. They can read and write to slaves (devices). The concept of master and slave is pretty common in software engineering, so I won’t elaborate more here.

However, in the case of the modbus protocol, the master is also called the client and physical devices such as the inverter above, are considered servers, or slaves. The master would be the one that initiates the connection to the slaves. I had assumed it was the other way around.

What remains the same is that, there can only be one master in a single modbus RTU network. (You can have multiple masters in a modbus TCP/IP network though I think.)

Slaves / Server

The slaves are the physical devices that you’re communicating with. They’re also called servers. They accept connections from the masters.

Multiple Modbus Masters?

For each of the connections defined in config.cfg, I created a Modbus connection. In this case, one was over RTU protocol and speaks over COM3 and one over TCP/IP.

My spindle was obviously a slave, and it accepts connections / commands from a master. But, I also needed live information from the spindle at the windows machine with Kepware. At first, I was hoping that I could achieve that by having a single Modbus slave to multiple Modbus masters (program + kepware). Unfortunately, that isn’t possible, at least over Modbus RTU.

To get around that, I got my program to issue commands to the spindle as a master, while periodically polling whatever required data from it, and relaying that information as a master to another slave- the Kepware instance.

Essentially, my program initiates and maintains two separate Modbus connections as a master.

libconfig

With regards to config files setup in my C program, coming ƒrom ruby and the web environment, YAML seemed like a natural choice. But I soon learned that, that’s not the case in C. I’m not sure what is the de-facto solution here, or if people used config files at all, but I eventually settled on libconfig. It was fairly simple to use and the interface was semi-clean I guess, even if a little convoluted.

It provides you a way to define nested lists and hashes.

connections = (
  {
    type = "rtu";
    rtu_port = "COM3";
    baud = 115200;
  },
  {
    type = "tcp";
    ip = "127.0.0.1";
    port = 502;
  }
);

Which you can then get from the program via something like

setting = config_lookup(&cfg, "connections");
int connections_count = config_setting_length(setting);
conn_arr = (struct ModbusConn *) malloc(sizeof(struct ModbusConn) * connections_count);

const char *type;
for (i = 0; i < connections_count; i++) {
  config_setting_t *connection = config_setting_get_elem(setting, i);
  config_setting_lookup_string(connection, "type", &type);
  ...
}

I know, it is a little long if you’re coming from ruby since all of those would be a single line of code. But hey, at least I’ve managed to encapsulate all the config stuff into config.h. From the main program, I just need to search/reference it for the configs!

struct ModbusDevice *plc = get_device(config, "hitachiwj200");
struct ModbusDevice *kep = get_device(config, "kepware");

libmodbus

The library that I was using to establish connections and construct the bytes to send to the devices was libmodbus, a library in C.

The gist of it is, you establish a connection.

if (modbus_connect(ctx) == -1) {
  fprintf(stderr, "Connection failed: %s\n", modbus_strerror(errno));
  modbus_free(ctx);
  exit(1);
}

And from there, by addressing directly to the register/coil memory locations you can set or read information through the protocol.

void set_coil(modbus_t *ctx, uint16_t addr_offset, bool setting)
{
  printf("Setting coil to %d\n", setting);
  if (modbus_write_bit(ctx, addr_offset, setting ? 1 : 0) != 1) {
    fprintf(stderr, "Failed to write to coil: %s\n", modbus_strerror(errno));
  }
}

The library implements all of the commands the protocol provides. You can read more about the commands at SimplyModbus. Each of the commands can be represented via some bytes (as with all things CS lol).

For instance, the modbus_read_registers method in libmodbus, is essentially Read Holding Registers on this page. The library helps you take care of

  • the slave address (which you do have to set beforehand),
  • the function code (that represents read_registers) and
  • the CRC.

You also have to manually pass in the rest of the parameters such as the memory location and the number of registers requested.

Tricky Memory Addressing

And this got a little tricky for me.

Each type of register / coil also have their designated memory locations and depending on the implementation of the library. For instance, single register memory locations might start from 40000 or 400001 depending on which library you use, and this is obviously quite a source of problem.

Something I found was useful with libmodbus is that it helps you with the first digit of the memory address if you point out which type it is. You could address a register at memory address 0 with libmodbus and I believe it would automatically map that to the appropriate memory address, say 400001 in the byte stream for the request it sends out to the slave.

Do note that different libraries might implement it differently and this can be a source of error in particular.

Configuring Kepware

I’m (also) not going to go into too much details with the configuration of Kepware since the vast majority of you who happen to read this article will not be paying the price tag on Kepware. But, I think it’s enough to say that, it is a piece of software that provides multiple drivers and UIs that come bundled with it to allow devices who might speak different protocols such as modbus, or OPC/UA (and a million others), to speak to each other without needing another piece of software to translate.

For the purpose of this project, it was set up on a Windows machine such that it would host a Modbus slave that accepts connections from my program, and would receive the data over Modbus TCP/IP as a slave and store the streamed byte data in an internal register that is universally accessible in Kepware by it’s other services e.g. the OPC/UA driver.

Virtual Serial Ports Via Pseudo Terminal

The above sections kinda ran through the setup that I built. This section is mostly on a quick way to run it locally without needing a COM port connected to the actual device at first. I found it troublesome to have to test my program with the actual spindle/hardware connected all the time so I looked for a way to simulate the Modbus RTU locally.

So far, I’ve found that the pseudo terminal works pretty well, okay except when it randomly stops emiting the stream data mysteriously heh. But, a restart of the socat stuff below usually fixes that.

I used virtual serial ports to test the program using the steps below:

$ brew install socat
$ socat -d -d pty,raw,echo=0 pty,raw,echo=0  # to get two pseudo terminals assigned.
$ cat < /dev/ttys035
$ echo "Test" > /dev/ttys037 # on a separate terminal

Socat is a CLI toolt that allows you to establish two bi-directional byte streams and allows a transfer of data between them. The commands in the snippet above, in combination, sets up the byte stream across /dev/ttys035 and /dev/ttys037 (psuedo terminals) so that any data sent from one end of it will be transmitted over to the other.

In other words, I could then get my program, which acts as a Modbus RTU master, to connect directly to /dev/ttys035 that has a Modbus RTU slave connected to it. And they can talk to each other in the modbus protocol flawlessly.

Wrapping Up

I hope this helps anyone out there who is trying to achieve the same thing and like me, doesn’t have a clue how or where to begin.

Anyways, after finishing development of the program on my Macbook, I eventually had to move this to a Windows machine running on Win 10. Despite the fact that C is relatively well-supported on Windows (I mean it’s just basically compiling to byte code), I had quite a hard time compiling it because of all that dll shit and hoops that Windows make you jump through, and some issues surrounding certain dependencies the program had. I did get everything to compile in MSVS 2017 eventually, but I think I’ll leave that story to Part 2 instead. If you wanna skip ahead, the project files can be found in the win32 folder!